Heat Hero Direct Manifold Part No: Heat Hero Direct

Heat Hero Direct is an open vented, gravity solid fuel heating system that has a built in cooling loop for safety

  • Open vented gravity fully pumped heating system
  • Direct heat to radiators & DHW
  • No heat exchanger on solid fuel boiler
  • No need to dig up floors
  • No need to change cylinder
  • Built in 44Kw cooling loop
  • Easily Installed

Read more product details …

Delivered: 1 - 2 working days (Ireland, Mainland EU)

539.93 438.97 exc VAT

3 in stock

Heat Hero Direct is an open vented, gravity solid fuel heating system that has a built in cooling loop for safety.   In the event of power failure, the thermal safety valve opens when the solid fuel boiler over heats and water mains flushes through a 44KW Stainless Steel Heat Exchanger which cools the primary flow and return coming from the solid fuel boiler.


The water from the solid fuel boiler is circulated directly throughout the heating system.  Solid fuel boilers can now be connected to single coil pressure cylinders and have a storage of over 300 litres of domestic hot water.  They can also be linked up with solar panels, oil boilers and high pressure gas boilers efficiently and safely.
Some of the benefits of Heat Hero Direct;



  • Can be used with single coil mains pressurised cylinders.

  • Can be used with single coil open vented cylinders.

  • No need to change the cylinder.

  • The water is pumped directly throughout the heating system without using a heat exchanger.

  • No electrical components or moving parts so no maintenance required.

  • Very easily installed and zoned.

  • Safety Cooling Circuit in the event of power cut.

  • Completely open vented system.

  • Requires an 8m circulation pump for strong circulation throughout the heating system.


INSTALLATION INSTRUCTIONS FOR DUAL HEATING SYSTEM:
Heat Hero Direct is installed above the solid fuel boiler to allow gravity pass through the solid fuel boiler and Heat Hero Direct.



  • The pipe thermostat must be of good quality and should be fitted as close to the solid fuel boiler as per diagrams. (Caution should be taken that the heat from the stove does notdamage the workings of the pipe thermostat.)

  • The circulation pump should be an 8m Head pump and should be fitted beside the Heat Hero Direct.

  • The Cold Feed must be connected to the Heat Hero Direct Port 5 (see page 6).

  • The Heating Storage Tank should be a minimum of 1m above the highest point of the heating System (e.g. above the Heat Hero Direct or above the radiators)

  • Expansion pipe of minimum ¾ “ diameter must be connected to the Heat Hero Direct Port 6 (see page 6) and piped to the heating tank as per diagram.

  • The Non return Valves should be of good quality and installed as per the diagram.

  • Auto air vents should be of good quality and installed as per the diagram.

  • Blow off valves should be installed at the secondary heat source.

  • Heating Zones If a heating system is zoned, At least one radiator zone must open automatically when the solid fuel thermostat turns on the circulating pump.

  • Pressurised Cylinder Heat Hero Direct can be connected with solar and a DHW pressurised cylinder safely and efficiently.

  • 44KW Cooling Loop is built into the Heat Hero Direct. If the solid fuel boiler heats above 99° the liquid filled temperature probe will open the thermal safety valve and mains water will cool the gravity circuit and the solid fuel boiler.

  • With Heat Hero Direct a solid fuel boiler, pressure cylinder, solar and oil or gas boiler can operate fully efficiently together within the manufacturers recommendations.


Specification

Part Number
Heat Hero Direct

Package Contents

1 x Heat Hero Direct Manifold.

Manuals / Datasheets